SMP准则修正的土压力在上海中心大厦基坑的应用研究 |
投稿时间:2019-04-16 修订日期:2019-05-15 点此下载全文 |
引用本文:姚正源.SMP准则修正的土压力在上海中心大厦基坑的应用研究[J].钻探工程,2019,46(6):83-87.YAO Zhengyuan. Application of earth pressure based on SMP failure criteria in foundation pit of Shanghai Center Tower[J]. Drilling Engineering, 2019,46(6):83-87. |
摘要点击次数: 1080 |
全文下载次数: 499 |
|
|
中文摘要:本文给出了基于SMP准则修正的土压力在主动区、被动区以及不同水土分合算条件下的计算公式,与上海中心大厦基坑土压力实测数据和朗肯土压力计算结果进行对比,结果表明:相较于朗肯土压力,基于SMP准则修正的土压力与实测值更为吻合,且有一定的安全储备。 |
中文关键词:SMP准则 土压力 朗肯土压力 基坑 上海中心大厦 |
|
Application of earth pressure based on SMP failure criteria in foundation pit of Shanghai Center Tower |
|
|
Abstract:This paper presents the calculation formula of earth pressure based on SMP failure criteria in the active zone, passive zone, and different soil and water conditions. The calculation results based on SMP failure criteria of Shanghai Center Tower is compared with the measured data and the calculation results of Rankine’s earth pressure. The results show that compared with that of Rankine’s earth pressure, the earth pressure based on SMP failure criteria is more consistent with the measured value, and provides some safety margin. |
keywords:SMP failure criteria earth pressure Rankine’s earth pressure foundation pit Shanghai Center Tower |
查看全文 查看/发表评论 下载PDF阅读器 |